Cross-linked versus conventional polyethylene for total knee arthroplasty: a meta-analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials.

We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all t...

متن کامل

Meta-analysis of navigation vs conventional total knee arthroplasty.

Navigated total knee arthroplasty (TKA) is promoted as a means to improve limb and prosthesis alignment. This study involved a systematic review and meta-analysis for all randomized controlled trials in the literature from 1986 to 2009 comparing alignment outcomes between navigated and conventional TKA. Alignment outcomes were pooled using a random-effects model, and heterogeneity was explored....

متن کامل

A Meta - Analysis Comparison of Navigated Versus Conventional Total Knee Arthroplasty

The prevalence of malalignment after total knee arthroplasty (TKA) can be as high as 25% at some centers (Knee. 2003 Mar;10[1]:55-60, and J Arthroplasty. 2001 Aug;16[5]:635-40). Typically, one of the goals is restoration of the mechanical axis to £3° of varus or valgus. One potential way to more accurately restore mechanical alignment and reduce outliers is through a custom-fit technique. This ...

متن کامل

[Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].

Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the litera...

متن کامل

Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial components of monoblock polyethylene design, as there is no backside wear. We investigated the effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Orthopaedic Surgery and Research

سال: 2016

ISSN: 1749-799X

DOI: 10.1186/s13018-016-0374-1