Cross contamination in dual inlet isotope ratio mass spectrometers

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross contamination in dual inlet isotope ratio mass spectrometers

Since the early days of geochemical isotope ratio mass spectrometry there has always been the problem of cross contamination, i.e. the contamination of the sample gas with traces of reference gas (and vice versa) in a dual inlet system and the analyzer itself. This was attributable to valve leakages and could be corrected for. In modern leak-free machines this problem still influences the measu...

متن کامل

Isotope Ratio Mass Spectrometry.

Isotope Ratio Mass Spectrometry (IRMS) is a specialized technique used to provide information about the geographic, chemical, and biological origins of substances. The ability to determine the source of an organic substance stems from the relative isotopic abundances of the elements which comprise the material. Because the isotope ratios of elements such as carbon, hydrogen, oxygen, sulfur, and...

متن کامل

Isotope-Ratio-Monitoring Gas Chromatography-Mass Spectrometry

RECEIVED for review February 21, 1978. Accepted June 19, 1978. NMR spectra since two distinct peaks (6 -3.38, 3.78 ppm) caused by these protons are observed in CDCA vs. only one peak (6 -3.45 ppm) caused by the same protons in UDCA. T h e fingerprint region of the spectrum (6 1-2.5 ppm) and the relative position of the CIS methyl peak with respect to tha t of the doublet caused by the Cpl methy...

متن کامل

Stable isotope ratio mass spectrometry in global climate change research

Stable isotope ratios of the life science elements carbon, hydrogen, oxygen and nitrogen vary slightly, but significantly in major compartments of the earth. Owing mainly to antropogenic activities including land use change and fossil fuel burning, the 13C/12C ratio of CO2 in the atmosphere has changed over the last 200 years by 1.5 parts per thousand (from about 0.0111073 to 0.0110906). In bet...

متن کامل

High precision isotope ratio monitoring techniques in mass spectrometry.

Isotope ratio monitoring following on-line combustion is a new method in gas chromatography/mass spectrometry (GC/MS) that allows the ratios of abundances of stable isotopes of elements such as carbon and nitrogen to be determined for individual compounds introduced via a gas chromatograph. It is the first combustion method that allows direct measurement of isotope ratios of individual molecula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Mass Spectrometry

سال: 2000

ISSN: 1387-3806

DOI: 10.1016/s1387-3806(99)00266-3