A double impulse input is used as a substitute for near-fault earthquake ground motions. An explicit expression is derived on the maximum elastic–plastic response of a singledegree-of-freedom damped structure with bilinear hysteresis under the “critical double impulse input” which causes the maximum response for variable impulse interval with the input level kept constant. Owing to the existenc...
متن کاملCritical Steady-State Response of Single-Degree-of-Freedom Bilinear Hysteretic System under Multi Impulse as Substitute of Long-Duration Ground Motion
Citation: Kojima K and Takewaki I (2017) Critical Steady-State Response of Single-Degree-of-Freedom Bilinear Hysteretic System under Multi Impulse as Substitute of Long-Duration Ground Motion. Front. Built Environ. 3:41. doi: 10.3389/fbuil.2017.00041 Critical Steady-State Response of Single-Degree-of-Freedom Bilinear Hysteretic System under Multi Impulse as Substitute of Long-Duration Ground Mo...
متن کاملCritical Response of 2DOF Elastic–Plastic Building Structures under Double Impulse as Substitute of Near-Fault Ground Motion
The double impulse is introduced as a substitute of the fling-step near-fault ground motion and a critical elastic–plastic response of a two-degree-of-freedom (2DOF) building structure under the “critical double impulse” is evaluated. Since only the free-vibration appears under such double impulse, the energy balance approach plays an important and essential role in the derivation of the soluti...
متن کاملResponse of Buildings with Inclined First-Story Columns to Near-Fault Ground Motion
In this paper a simple model of a three story building with inclined first-story columns has presented. The stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational dampers. The considered model is subjected to horizontal component of fault normal pulse with different magnitudes and the governed nonlinear di...
متن کاملSliding Mode Control for Single-degree-of-freedom Nonlinear Structures
The occurrence of catastrophic earthquakes necessitates further researches in the structure engineering for retrofitting construction structures. In this paper, the application of the active control in the structures’ seismic response has been addressed. A single degree of freedom nonlinear structure has been studied. The nonlinear dynamic of the structure is considered in which, the nonlinear ...