Crevice corrosion of titanium and its prevension.
نویسندگان
چکیده
منابع مشابه
Combining Rigorously Controlled Crevice Geometry and Computational Modeling for Study of Crevice Corrosion Scaling Factors
Microfabrication methods have been used to construct crevice formers of rigorously controlled gap and length. These have been used to study the IR-controlled crevice corrosion of Ni200 in 0.5 M H2SO4 to determine the effect of crevice gap ~G! on the position of the accelerated attack (xcrit) within the crevice. The experimental results were then compared to the results of computational studies....
متن کاملCombining the Ohmic Drop and Critical Crevice Solution Approaches to Rationalize Intermediate Attack in Crevice Corrosion
Crevice corrosion material loss is often most severe at intermediate distances into the crevice. This intermediate attack can be rationalized using the ohmic drop model of Pickering if and only if the material in question exhibits active/passive behavior in the crevice environment. Conventional theories that ascribe control of crevice corrosion to chemical changes exclusively cannot rationalize...
متن کاملBiofouling of Titanium – Biomineralization and Corrosion Aspects
Manganese oxidizing bacteria colonizing the titanium surfaces exposed to seawater were characterized by periodically retrieving the coupons over a period of two years. About 20% of the initial colonizers were capable of oxidizing manganese, and the dominant manganese oxidizing bacteria were those belonging to Gram negative Pseudomonas spp. Gram positive, Bacillus spp, were also observed, though...
متن کاملthe study of practical and theoretical foundation of credit risk and its coverage
پس از بررسی هر کدام از فاکتورهای نوع صنعت, نوع ضمانت نامه, نرخ بهره , نرخ تورم, ریسک اعتباری کشورها, کارمزد, ریکاوری, gdp, پوشش و وثیقه بر ریسک اعتباری صندوق ضمانت صادرات ایران مشخص گردید که همه فاکتورها به استثنای ریسک اعتباری کشورها و کارمزد بقیه فاکتورها رابطه معناداری با ریسک اعتباری دارند در ضمن نرخ بهره , نرخ تورم, ریکاوری, و نوع صنعت و ریسک کشورها اثر عکس روی ریسک اعتباری داردو پوشش, وثی...
15 صفحه اولCorrosion of cemented titanium femoral stems.
Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem ebonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Surface Finishing Society of Japan
سال: 1989
ISSN: 0915-1869,1884-3409
DOI: 10.4139/sfj.40.1091