Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...
متن کاملA new active thermal neutron detector.
This communication presents the main results about the design and in-house fabrication of a new solid-state neutron detector, which produces a DC output signal proportional to the thermal neutron fluence rate. The detector has been developed within the framework of the 3-y project NESCOFI@BTF of INFN (CSN V). Due to its sensitivity, photon rejection, low cost and minimum size, this device is su...
متن کاملNeutron dosimetry
R É S U M É En dosimétrie des neutrons, les situations pratiques rencontrées couvrent un large domaine d'énergie s'étendant sur plus de 10 décades. En outre, les grandeurs dosimétriques utilisées en radioprotection ne sont pas directement accessibles à la mesure. Ce dernier point est principalement dû à la variation de la "qualité" du rayonnement neutronique, exprimé au moyen des facteurs de po...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملThe nuclear track detector CR39: results from different experiments
The nuclear track detector CR39 was calibrated with different ions of different energies. Due to the low detection threshold (Z/β ∼ 6e) and the good charge resolution (σZ ∼ 0.2e for 6e ≤ Z/β ≤ 83e with 2 measurements), the detector was used for different purposes: (i) fragmentation of high and medium energy ions; (ii) search for magnetic monopoles, nuclearites, strangelets and Q-balls in the co...