Coupling of high-intensity ultrasound and mechanical stirring for producing food emulsions at low-energy densities
نویسندگان
چکیده
منابع مشابه
Low intensity ultrasound mechanical index as a parameter affecting of ability of proliferation and collagene type 1 expression of cells
Introduction: Mechanical index (MI) is used for quantifying acoustic cavitation and the relationship between acoustic pressure and the frequency. In this study, modeling of the MI was applied to provide treatment protocol and to understand the effective physical processes on reproducibility and gene expression of fibroblast cells. Skin damage can occur of burn, cuts, abrasions ...
متن کاملA High Intensity Linear Ee Collider Facility at Low Energy
The huge luminosity increase compared to existing ring colliders is expected by using linear collider concepts. The luminosities of past and existing ee ring colliders have been steadily increased mainly by increasing the beam currents and collision frequencies. The design luminosities of various ee ring colliders are shown in Fig. 1 as function of the beam energy. A main limitation comes from ...
متن کاملIn vivo photoacoustics and high frequency ultrasound imaging of mechanical high intensity focused ultrasound (HIFU) ablation.
The thermal effect of high intensity focused ultrasound (HIFU) has been clinically exploited over a decade, while the mechanical HIFU is still largely confined to laboratory investigations. This is in part due to the lack of adequate imaging techniques to better understand the in-vivo pathological and immunological effects caused by the mechanical treatment. In this work, we explore the use of ...
متن کاملPump-Probe Experiments at High Energy Densities Performed at PHELIX
Matter at extremes of density and temperature occurs widely in astrophysical objects such as giant gas planets or highly evolved stars. Accurate modelling of matter at high energy density (HED) is of great importance in understanding the structure and evolution of these objects [1]. Creation of electromagnetic HED plasmas in the laboratory requires very powerful drivers. Intense heavy ion pulse...
متن کاملTHE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR
We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasonics Sonochemistry
سال: 2018
ISSN: 1350-4177
DOI: 10.1016/j.ultsonch.2018.04.020