Coupling DFIG-Based Wind Turbines with the Grid under Voltage Imbalance Conditions

نویسندگان

چکیده

A smooth coupling is implemented between the grid and doubly fed induction generator-based wind turbines (DFIG-WTs) during voltage imbalance. The nonlinear characteristics of a grid-connected DFIG-WT system may increase stresses on mechanical electrical components turbines. Such difficulties are greatly increased periods Consequently, in this paper, new control scheme proposed to regulate DFIGs order support connection In synchronization mode, positive sequence rotor dq-axes currents regulates stator q-axis EMF that be synchronized with grid-side voltage. phase difference voltages compensated by adjusting d-axis zero. Under normal conditions, PR controller used dampen negative currents. PI current controllers tuned DFIG currents, while under operation conditions. Experiments performed verify robustness

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips

This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...

متن کامل

Coordinated Control of a DFIG-Based Wind-Power Generation System with SGSC under Distorted Grid Voltage Conditions

Abstract: This paper presents a coordinated control method for a doubly-fed induction generator (DFIG)-based wind-power generation system with a series grid-side converter (SGSC) under distorted grid voltage conditions. The detailed mathematical models of the DFIG system with SGSC are developed in the multiple synchronous rotating reference frames. In order to counteract the adverse effects of ...

متن کامل

Stability Augmentation of a Grid-Connected Wind Farm by Fuzzy-Logic-Controlled DFIG-Based Wind Turbines

Md. Rifat Hazari 1,* ID , Mohammad Abdul Mannan 2, S. M. Muyeen 3, Atsushi Umemura 1, Rion Takahashi 1 and Junji Tamura 1 1 Department of Electrical and Electronic Engineering, Kitami Institute of Technology (KIT), 165 Koen-cho, Kitami, Hokkaido 090-8507, Japan; [email protected] (A.U.); [email protected] (R.T.); [email protected] (J.T.) 2 Department of Electrical...

متن کامل

A Novel Control Scheme for DFIG-based Wind Energy Systems under Unbalanced Grid Conditions

This paper presents an analysis and a novel control scheme for a doubly-fed induction generator (DFIG) based wind energy generation under unbalanced grid conditions. The control objectives are: (i) to limit the rotor currents, (ii) to suppress ripples in the torque and (iii) to suppress the dc-link voltage fluctuation through converter controls. Negative sequence compensation techniques by one ...

متن کامل

Improvement of Transient Voltage Profile Using Power Control of the DFIG-Based Wind Farm Under Severe Voltage Dip Event

Improving transient voltage stability is one of the most important issues that must be provided by doubly fed induction generator (DFIG)-based wind farms (WFs) according to the grid code requirement. This paper proposes adjusted DC-link chopper based passive voltage compensator and modified transient voltage controller (MTVC) based active voltage compensator for improving transient voltage stab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sustainability

سال: 2022

ISSN: ['2071-1050']

DOI: https://doi.org/10.3390/su14095076