Cost-Effectiveness of Transtibial Bone-Anchored Prostheses Using Osseointegrated Fixation: From Challenges to Preliminary Data
نویسندگان
چکیده
Introduction This initial cost-effectiveness evaluation compared the provision of transtibial bone-anchored prostheses (TTA-BAPs) with socket-suspended (TTA-SSPs) over a 6-year time horizon from governmental prosthetic care perspective. The purposes were to present ways we dealt barriers encountered during analysis. objectives detail extraction baseline and incremental costs utilities required provide preliminary ratios (ICERs) per quality-adjusted life-year (QALY). Materials Methods retrospective case-series study involved six participants fitted consecutively TTA-SSP TTA-BAP. Total combined actual typical extracted financial records schedule allowable expenses, respectively. Baseline literature, whereas assumed. Results ICERs ranged between ?$25,065 $41,929 QALY. Indicative ICER was approximately $11,400 Provision TTA-BAP cost-effective cost saving for 83% 33% cases, Discussion Educated choices overcome unavailability individual (e.g., creation blending costs) assumptions gain). might lead adoption TTA-BAP, at least an Australian
منابع مشابه
Cost-effectiveness analysis of the bone-anchored hearing device.
OBJECTIVE To establish the cost-effectiveness of a bone-anchored hearing device (BAHD). To date, there has not been any formal economic analysis of this treatment. STUDY DESIGN A prospective cohort case-control analysis. SETTING Tertiary referral center, university hospital. PATIENTS Between April 2007 and June 2008, all adult patients undergoing their first BAHD were contacted and invite...
متن کاملCost of placement and complications associated with osseointegrated bone-conducting hearing prostheses: a retrospective analysis of medicare billing data.
OBJECTIVE To report the cost of placement and complications related to osseointegrated bone-conducting hearing prostheses (OBHPs) in a Medicare population. MATERIALS AND METHODS We performed a retrospective analysis of nationwide Medicare claims data for operative and nonoperative complications associated with the placement of percutaneous OBHPs between the first quarter of 2007 and the secon...
متن کاملOsseointegrated Finger Prostheses Using a Tripod Titanium Mini-Plate
BACKGROUND Digital amputation is a common upper extremity injury and can cause significant impairment in hand function, as well as psychosocial stigma. Currently, the gold standard for the reconstruction of such injuries involves autologous reconstruction. However, when this or other autologous options are not available, prosthetic reconstruction can provide a functionally and aesthetically via...
متن کاملNumerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss.
Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system, Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining biomechanical issues such as considerable bone loss around the stem and peri-prosthetic bone fractures are p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jpo Journal of Prosthetics and Orthotics
سال: 2021
ISSN: ['1040-8800', '1534-6331']
DOI: https://doi.org/10.1097/jpo.0000000000000372