CORROSION INHIBITION BY RARE EARTH CHLORIDES FOR 2219-T87 ALUMINIUM ALLOY IN SEAWATER
نویسندگان
چکیده
منابع مشابه
Localized Corrosion on 2219 Aluminium Alloy Coated with a Titanium Based Conversion Coating
High strength aluminium alloys are widely employed in aerospace applications. However specific environmental conditions may trigger corrosion and therefore these alloys require additional protection. Most current conversion coatings used for this purpose are Cr(VI) based, and thus environmentally undesirable. A possible replacement is a Ti based coating, Nabutan STI/310. The aim of this work is...
متن کاملLOCALIZED CORROSION OF A 2219 ALUMINIUM ALLOY EXPOSED TO A 3.5% NaCl SOLUTION
This work is focused on the role of intermetallics in pitting corrosion of Al2219 alloy. Second phase particles were characterized by AES, SAM and EDX. Their behaviour in a solution of NaCl was investigated as a function of exposure time. The results confirmed the cathodic nature of the intermetallics with respect to the aluminium matrix. Corrosion products rich in aluminium and oxygen were fou...
متن کاملCORROSION BEHAVIOUR OF A 2219 ALUMINIUM ALLOY TREATED WITH A CHROMATE CONVERSION COATING EXPOSED TO A 3.5 % NaCl SOLUTION
This study investigates the formation of a chromate conversion coating at Al-Cu-Fe-Mn intermetallic sites of an Al2219 alloy and the corrosion initiation at these sites in a 3.5 % NaCl solution, using SEM, AES and EDX. Changes in the surface chemistry were monitored after progressive exposures to the solution up to 42 hours. The coating was found to be thinner and more defective on the intermet...
متن کاملSome physical properties of rare-earth chlorides in aqueous solution
The aqueous solution behavior of some rare-earth chlorides has been investigated at 25° C. in the concentration range between 0.02 molal and saturation. Density measurements on solutions of lanthanum, neodymium, samarium, gadolinium, dysprosium, erbium, and ytterbium chlorides were carried out by a pycnometric method with an estimated accuracy of 1 x 10-5 gm.per ml. From the density data the ap...
متن کاملStudies of Corrosion of Aluminium and 6063 Aluminium Alloy in Phosphoric Acid Medium
The corrosion behaviour of aluminium and6063 aluminium alloy was investigated in phosphoric acid of different concentrations at different temperatures. The study was done by electrochemical method, using Tafel polarization and electrochemical impedance spectroscopy (EIS) techniques. The kinetic parameters and thermodynamic parameters were calculated using Arrhenius theory and transition state t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal on Design and Manufacturing Technologies
سال: 2013
ISSN: 0973-9106
DOI: 10.18000/ijodam.70126