Corrosion and Hydrogen Permeation in H2S Environments with O2 Contamination, Part 2: Impact of H2S Partial Pressure
نویسندگان
چکیده
منابع مشابه
Ru(EDTA) mediated partial reduction of O2 by H2S.
An effective procedure for selective reduction of O2 to H2O2 exploring the use of hydrogen sulfide, an obnoxious industrial pollutant as reductant is reported herein. The reduction of [Ru(III)(EDTA)pz](-) (EDTA(4-) = ethylenediaminetetraacetate; pz = pyrazine) by hydrogen sulfide resulting in the formation of a red [Ru(II)(EDTA)pz](2-) complex (λmax = 462 nm) has been studied spectrophotometric...
متن کاملEIS investigation of CO2/H2S corrosion
This paper covers one of the building blocks required to complete a mechanistic CO2 / H2S corrosion model: electrochemistry of carbon steel CO2 corrosion in the presence of traces of H2S (3-250 ppm in the gas phase). Electrochemical impedance spectroscopy and linear polarisation resistance were used to investigate the mechanism of CO2/H2S corrosion in a glass cell at room temperature, at atmosp...
متن کاملH2S mediates O2 sensing in the carotid body.
Gaseousmessengers, nitric oxide and carbon monoxide, have been implicated in O2 sensing by the carotid body, a sensory organ that monitors arterial blood O2 levels and stimulates breathing in response to hypoxia. We now show that hydrogen sulfide (H2S) is a physiologic gasotransmitter of the carotid body, enhancing its sensory response to hypoxia. Glomus cells, the site of O2 sensing in the car...
متن کاملExogenous Hydrogen Sulfide (H2S) Protects Alveolar Growth in Experimental O2-Induced Neonatal Lung Injury
BACKGROUND Bronchopulmonary dysplasia (BPD), the chronic lung disease of prematurity, remains a major health problem. BPD is characterized by impaired alveolar development and complicated by pulmonary hypertension (PHT). Currently there is no specific treatment for BPD. Hydrogen sulfide (H2S), carbon monoxide and nitric oxide (NO), belong to a class of endogenously synthesized gaseous molecules...
متن کاملCorrosion in Multiphase Flow Containing Small Amounts of H2s
Experiments in a large-scale flow loop provide an example of a somewhat increased corrosion rate under multiphase flow conditions caused by a low concentration of H2S in a CO2 saturated environment. Under operating conditions that prevent scale formation, the addition of 3ppm H2S in the gas phase increased the corrosion rate of AISI C 1018 and API 5L X-65 carbon steels, while the addition of H2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: CORROSION
سال: 2018
ISSN: 0010-9312,1938-159X
DOI: 10.5006/3092