Corrosion analysis of guyed rod used for 500 kV transmission tower
نویسندگان
چکیده
منابع مشابه
Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks
This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground condu...
متن کاملPrediction of Egyptian 500 kV Overhead Transmission lines Radio- Interference by Using the Excitation Function
This paper presents applications of the excitation function on the prediction of the RadioInterference (RI) of overhead transmission line, due to corona effect. These applications are done under different weather conditions such as: heavy rain, wet conductor and fair weather. Also, this paper investigates the factors influencing the RI level namely; the height of conductors, phase spacing, numb...
متن کاملanalysis of ruin probability for insurance companies using markov chain
در این پایان نامه نشان داده ایم که چگونه می توان مدل ریسک بیمه ای اسپیرر اندرسون را به کمک زنجیره های مارکوف تعریف کرد. سپس به کمک روش های آنالیز ماتریسی احتمال برشکستگی ، میزان مازاد در هنگام برشکستگی و میزان کسری بودجه در زمان وقوع برشکستگی را محاسبه کرده ایم. هدف ما در این پایان نامه بسیار محاسباتی و کاربردی تر از روش های است که در گذشته برای محاسبه این احتمال ارائه شده است. در ابتدا ما نشا...
15 صفحه اولA Simplified Method for Dynamic Analysis of a Guyed Mast
The dynamic response of a guyed mast is relatively larger than for other structures. Thus a proper evaluation of the dynamic response is of major importance. The proposed simplified method separates the dynamic response into a low-frequency, background region and a high-frequency, resonant region. The background response has been estimated using patch loading. The resonant responses can be take...
متن کاملINITIAL PERFORMANCE OF A 500 kV, CHOPPER PREBUNCHER INJECTION SYSTEM FOR A 17 GHz LINAC*
The design features of a 17 GHz chopper prebuncher injection system are described, and initial test results operating with a 500 kV low emittance electron gun and single section 17 GHz linac are presented. The 17 GHz traveling wave relativistic klystron that provides RF power to the linac structure, and the 500 kV electron gun that forms the low emittance (βγ ε = 3π mm-mradian) source for the i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2021
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1939/1/012029