Corresponding dose response of radiographic film with layered gafchromic film.

This note investigates the dose response of layered HS Gafchromic film compared to Kodak EDR-2 radiographic film. Using five layers of HS type Gafchromic film a dose response greater than EDR-2 film is achieved at the peak wavelength (0.55 OD/Gy versus 0.3 OD/Gy for EDR-2 film). Even over a broader waveband of 30 nm, which is similar to that found in ultra bright LED scanners, the response was ...

متن کامل

Surface dose extrapolation measurements with radiographic film.

Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown...

متن کامل

Response of GafChromic MD-55 film to synchrotron radiation

Introduction Recently, owing to the increase of synchrotron radiation facilities such as SPring-8, dose measurements of high-intense low-energy photons are increasingly needed for radiation protection and medical researches. For the dose measurement, tissue equivalence of dosimeter material becomes important. A radiochromic film that has sensitivity in the dose region of several Gy to 100 Gy ha...

متن کامل

Dosimetric characterization of GafChromic EBT film

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

متن کامل

dose response of irradiated xrct radiochromic film

– gafchromic xrct radiochromic film is a self developing high sensitivity radiochromic filmproduct which can be used for assessment of delivered radiation doses which could match applications suchas computed tomography (ct) dosimetry. the dose response of gafchromic xrct radiochromic film hasbeen measured with reflectance spectrophotometry and desktop scanners. the film automatically changescol...

متن کامل