Correction to: An Innovative Tuned Liquid Damper for Vibration Mitigation of Structures
نویسندگان
چکیده
A correction to this paper has been published: https://doi.org/10.1007/s40999-021-00639-3
منابع مشابه
Comparative Performance Study of Tuned Liquid Column Ball Damper for Excessive Liquid Displacement on Response Reduction of Structure
The tuned liquid column damper (TLCD) having a uniform cross-sectional tube of U-shaped, occupied with liquid is used as a vibrational response mitigation device. The tuned liquid column ball damper (TLCBD) is a modified TLCD, where, an immovable orifice, positioned at the middle part of the horizontal portion, is replaced by a metal ball. Different studies on the unconstrained optimization per...
متن کاملPerformance of Tuned Liquid Dampers with Different Tank Geometries for Vibration Control of Structures
TLD is a tank filled with water and serves as a dynamic vibration absorber for passive control of structures. This paper addresses the comparisons of TLD performances corresponding to different tank geometries including rectangular and conical shapes. Due to the importance of water and tank weight as a load on top of a building, volume is considered to be a constant parameter in this study. Fir...
متن کاملearthquake vibration control of structures using tuned liquid dampers: experimental studies
earlier studies have shown conclusively that a tuned liquid damper (tld) is effective for controlling vibrations in structures subjected to narrow-banded wind excitations. a recent numerical study has shown that if the design parameters of a tld are properly set, this device could also be very effective for controlling structural vibration to broad-banded earthquake excitations. here the result...
متن کاملOPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...
متن کاملExperimental Study on Using Uniform Tuned Liquid Column Damper for Structural Control of Buildings Resting on Loose Soil
In this study, through series of shaking table tests and statistical analysis, the efficiency of Uniform Tuned Liquid Column Damper (UTLCD) in structures resting on loose soils, considering soil-structure interaction was investigated. The soil beneath the structure is loose sandy soil. The Laminar Shear Box (LSB) as a soil container was adopted and the scaled form of the prototype structure nam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Civil Engineering
سال: 2021
ISSN: ['2383-3874', '1735-0522']
DOI: https://doi.org/10.1007/s40999-021-00639-3