Correction of non-linearity effects in detectors for electron spectroscopy
نویسندگان
چکیده
منابع مشابه
Correction of Non-Linearity Effects in Detectors for Electron Spectroscopy
N. Mannella, 2, ∗ S. Marchesini, † A. W. Kay, 2, ‡ A. Nambu, 3 T. Gresch, 4 S.-H. Yang, § B. S. Mun, 2, ¶ J. M. Bussat, A. Rosenhahn, ∗∗ and C. S. Fadley 2 Department of Physics, UC Davis, Davis, CA, USA Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA Department of Physics, University of Tokyo, Tokyo, Japan Institute of Physics, University of Zurich, Zurich...
متن کاملthe effects of error correction methods on pronunciation accuracy
هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...
15 صفحه اولNon-Linearity Correction Algorithm for the WFC3 IR Channel
WFC3 IR channel data are obtained in the form of multiple, non-destructive readouts, grouped into “ramps”, similar to the method employed by NICMOS. This strategy facilitates the characterization of the non-linearity of the IR Focal Plane Array (FPA), as the detector’s response to a steady signal can be measured multiple times, until the detector becomes saturated. Using test data collected in ...
متن کاملNon-linearity Correction of ADCs in Software Radio Systems
The paper presents the results of the experimental validation of a method for digital compensation of ADC non-linearity errors. First, the theory underlying the method is briefly described. Then, the compensation method has been validated both on sinusoidal signals and on 3 generation mobile telecommunication signals, compliant to 3GPP specifications.
متن کاملEffects, determination, and correction of count rate nonlinearity in multi-channel analog electron detectors.
Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We focus on a nearly ubiquitous "inverse saturation" nonlinearity that makes the spectra falsely sharp and beautiful. These artificially enhanced spectra limit ac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electron Spectroscopy and Related Phenomena
سال: 2004
ISSN: 0368-2048
DOI: 10.1016/j.elspec.2004.03.009