Correcting Low-Frequency Noise with Continuous Measurement
نویسندگان
چکیده
منابع مشابه
A New Ultra-Wideband Low Noise Amplifier With Continuous Gain Control
This paper presents a new variable gain low noise amplifier (VG-LNA) for ultra-wideband (UWB) applications. The proposed VG-LNA uses a common-source (CS) with a shunt-shunt active feedback as an input stage to realize input matching and partial noise cancelling. An output stage consists of a gain-boosted CS cascode and a gain control circuit that moves the high resonant frequency to higher freq...
متن کاملLow Noise Measurement of Photocurrent for Continuous Glucose Monitoring - Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid
The purpose of this work is mainly to manufacture several anatomical models in a polymeric material – polydimensiloxane (PDMS) to study the blood flow through a carotid artery bifurcation. Over the last few decades, research has been shown that the geometry of the carotid artery is closely related to the development of serious cardiovascular diseases. Hence, there is a considerable interest in ...
متن کاملLow frequency noise "pollution" interferes with performance.
To study the possible interference of low frequency noise on performance and annoyance, subjects categorised as having a high- or low sensitivity to noise in general and low frequency noise in particular worked with different performance tasks in a noise environment with predominantly low frequency content or flat frequency content (reference noise), both at a level of 40 dBA. The effects were ...
متن کاملDesign of an S-band Ultra-low-noise Amplifier with Frequency Band Switching Capability
In this paper, an ultra-low-noise amplifier with frequency band switching capability is designed, simulated and fabricated. The two frequency ranges of this amplifier consist of the 2.4 to 2.5 GHz and 3.1 GHz to 3.15 GHz frequency bands. The designed amplifier has a noise figure of less than 1dB, a minimum gain of 23 dB and a VSWR of less than 2 in the whole frequency band. The design process s...
متن کاملLow-current Noise Measurement Techniques
The noise of a resistive sample is a measurable physical property. The noise signature can depend on such variables as the materials used in preparing a sample and the method used to prepare it. A versatile experimental technique is needed to measure these noise signatures, one which can be applied to any form of resistive structure. In addition, many samples with unique physical properties, su...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Letters
سال: 2007
ISSN: 0031-9007,1079-7114
DOI: 10.1103/physrevlett.98.153602