Correcting dynamic distortions in 7T echo planar imaging using a jittered echo time sequence
نویسندگان
چکیده
منابع مشابه
Correcting dynamic distortions in 7T echo planar imaging using a jittered echo time sequence
PURPOSE To develop a distortion correction method for echo planar imaging (EPI) that is able to measure dynamic changes in B0 . THEORY AND METHODS The approach we propose is based on single-echo EPI with a jittering of the echo time between two values for alternate time points. Field maps are calculated between phase images from adjacent volumes and are used to remove distortion from correspo...
متن کاملCorrection for EPI distortions using multi-echo gradient-echo imaging.
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
متن کاملHow to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging.
Diffusion tensor imaging is often performed by acquiring a series of diffusion-weighted spin-echo echo-planar images with different direction diffusion gradients. A problem of echo-planar images is the geometrical distortions that obtain near junctions between tissues of differing magnetic susceptibility. This results in distorted diffusion-tensor maps. To resolve this we suggest acquiring two ...
متن کاملDynamic Susceptibility Contrast Imaging using a multi-echo spiral sequence
Introduction To characterize microvasculature, one can perform a DCE-MRI experiment (a first injection of contrast agent (CA) to estimate the vessel wall permeability) followed by a DSC-MRI experiment (a second injection of CA to estimate relative blood volume (rCBV), relative blood flow, etc.) [1]. The DSC experiment can even yield information on vessel size if a gradient echo and a spin echo ...
متن کاملEcho-planar imaging.
Echo-planar imaging is a fast magnetic resonance (MR) imaging technique that allows acquisition of single images in as little as 20 msec and performance of multiple-image studies in as little as 20 seconds. Echo-planar imaging achieves its speed by obtaining all spatial-encoding information after a single radio-frequency (RF) excitation. Conventional imaging requires multiple-RF excitations, se...