منابع مشابه
The coronary sinus reducer for the treatment of refractory angina
We were very interested to read the recently published manuscript ‘Safety and efficacy of a device to narrow the coronary sinus for the treatment of refractory angina: A single-centre real-world experience’ by Masieh Abawi et al. [1]. Some people make a mistake and compare the coronary sinus reducer (CSR) with the Beck procedure (Beck operation), but actually the Beck procedure has almost nothi...
متن کامل[The coronary sinus reducer stent for the treatment of chronic refractory angina pectoris].
We were very interested to read the article dealing with therapeutic options in patients with chronic refractory angina pectoris (RAP) signed by Cohen et al. 1 The authors presented an excellent review of the therapeutic options for such ''no-option'' patients suffering from chronic RAP caused by severe symptomatic and chronic coronary artery disease. May we quote Dr. Cohen and colleagues: ''Re...
متن کاملCoronary Sinus Reducer Stent for the Treatment of Chronic Refractory Angina Pectoris
Background Increased coronary sinus (CS) pressure can reduce myocardial ischemia by redistribution of blood from nonischemic to ischemic territories. The Coronary Sinus Reducer is a percutaneous implantable device designed to establish CS narrowing and to elevate CS pressure. In preclinical experiments, implantation of the Reducer was safe and was associated with improved ischemic parameters. I...
متن کامل[the Coronary Sinus Reducer: a Device-based Therapy for Refractory Angina].
INTRODUCTION Alongside the remarkable progress in therapeutic strategies destined to patients with coronary artery disease (CAD), a growing number of patients who suffer from severe and diffuse CAD not amenable for revascularization, continue to experience severe debilitating angina despite optimal medical therapy. The Coronary Sinus (CS) Reducer has emerged as a novel therapeutic strategy for ...
متن کاملCoronary sinus dissection during left ventricular pacing electrode implantation.
Coronary sinus (CS) dissection during biventricular pacing electrode implantation is a complication that rarely develops. A 71-year-old female with recurrent ventricular tachycardia, heart decompensation, and poor left ventricular function because of dilated cardiomyopathy was admitted for the implantation of a cardioverter-defibrillator for biventricular pacing. During the operation, we experi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Interventions
سال: 2018
ISSN: 1936-8798
DOI: 10.1016/j.jcin.2018.05.018