Coronary sinus pacing clinical follow-up.
Coronary sinus pacing is a safe and effective means of pacing from the atrium. In 66 patients with an average follow-up of 14 months, there was a 14% failure rate. There were transient problems in 14% which were subsequently corrected. There was a 6% death rate which was not pacemaker related. Successful atrial pacing with thresholds up to 6.0 mA is feasible. Atrial pacing was successful in 18 ...
متن کاملCoronary sinus dissection during left ventricular pacing electrode implantation.
Coronary sinus (CS) dissection during biventricular pacing electrode implantation is a complication that rarely develops. A 71-year-old female with recurrent ventricular tachycardia, heart decompensation, and poor left ventricular function because of dilated cardiomyopathy was admitted for the implantation of a cardioverter-defibrillator for biventricular pacing. During the operation, we experi...
متن کاملLong-term electrode catheter pacing from coronary sinus.
Medical Memoranda B ,m 495 about two hours after the cardiac arrest that the pulmonary obstruction was bypassed. Post-mortem examination showed a tear in the left lobe of the liver and the haemoperitoneum, but no residual pulmonary emboli. COMMENT Massive pulmonary embolism often defies definitive clinical diagnosis. Cross and Mowlem (1967) reported a mortality of 100% in nine cases of erroneou...
متن کاملAntegrade visualisation of the coronary sinus for left ventricular pacing.
INTRODUCTION Failure to achieve left ventricular pacing remains one of the obstacles to cardiac resynchronisation therapy. METHODS A new technique for the placement of left ventricular pacing leads in the tributaries of the coronary sinus is described. Antegrade visualisation of the coronary sinus is accomplished by selective coronary angiography and a hydrophilic 0.032" wire is advanced alon...
متن کاملTraumatic atrial septal defect and coronary sinus to left atrium fistula from coronary sinus pacing lead removal.
CARDIAC resynchronization therapy with the placement of a left ventricular pacing electrode in the coronary sinus has been shown to be an effective treatment in selected patients with symptomatic left ventricular dysfunction. Coronary sinus leads can be removed with relative ease because of their small diameter and relatively poor fixation mechanisms. However, removal of coronary sinus electrod...