Comparison of central corneal thickness measured with anterior segment optical coherence tomography versus ultrasonic pachymetry.
PURPOSE To compare central corneal thickness measured with anterior segment optical coherence tomography (AS-OCT) and ultrasonic pachymetry (UP). METHOD A prospective, observational and cross-sectional study was performed. The central corneal thickness was measured in 112 eyes of 112 consecutive patients with AS-OCT and UP. All examinations were performed by the same examiner. The measurement...
متن کاملComparison of optical coherence reflectometry and ultrasound central corneal pachymetry.
In 50 eyes of 25 patients we prospectively measured the central corneal thickness (CCT) comparing the OLCR (Optical Low Coherence Reflectometry) pachymeter with the contact ultrasound pachymeter. The OLCR system was mounted on to a Haag-Streit slit lamp. Every single measurement was the result of 5 scans. With the contact ultrasound Sonomed pachymeter we performed 5 separate measurements and ca...
متن کاملIn vivo corneal high-speed, ultra high-resolution optical coherence tomography.
OBJECTIVE To introduce new corneal high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT) technology that improves the evaluation of complicated and uncomplicated cataract, corneal, and refractive surgical procedures. DESIGN This case series included a control subject and 9 eyes of 8 patients who had undergone phacoemulsification, Descemet membrane stripping endokeratoplas...
متن کاملWide Corneal Epithelial Mapping Using an Optical Coherence Tomography.
Purpose To map the corneal epithelium using a map measuring 9 mm in diameter and view the effects of age, sex, and axial length. Additionally, we wanted to demonstrate the reproducibility of this technique. Methods We calculated the epithelial thickness in 220 individuals using an SD-OCT machine with the newly released commercially available algorithm. We included normal eyes with refractive ...
متن کاملContinuous non-contact corneal pachymetry with a high speed reflectometer.
PURPOSE We developed an instrument that permits non-contact, continuous, high speed and high precision monitoring of corneal thickness and tested the stability and reproducibility of measurements made over extended time periods and under various conditions of low surface reflectivity encountered during protracted exposure of the unmoistened corneal surface to ambient air. METHODS The optical ...