Corneal Buckling during Applanation and Its Effect on the Air Pressure Curve in Ocular Response Analyzer
نویسندگان
چکیده
منابع مشابه
intraocular pressure measurements after penetrating keratoplasty using the ocular response analyzer versus goldmann applanation tonometer
purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 kerat...
متن کاملevaluation of corneal biomechanical properties following scleral buckling using the ocular response analyzer
purpose : to evaluate corneal visco-elasticity and intraocular pressure (iop) changes measured by an ocular response analyzer (ora) after scleral buckling methods : fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. corneal hysteresis (ch), corneal resistance factor (crf), corneal-compensated iop (iopcc) and goldmann-correlated iop (iopg) were m...
متن کاملMeasurement and analysis of the air pressure curve on the rigid lenses by use of ocular response analyzer.
PURPOSE Pressure curves obtained from Ocular Response Analyzer (ORA) differ for the same patient in form and height. In some cases measurements on the subject show significant differences between recorded pressure curves. The purpose of the paper is to examine if the differences result from the corneal properties or from the device operation. METHODS Examination of air pressure curves was car...
متن کاملEvaluation of Corneal Biomechanical Properties following Scleral Buckling Using the Ocular Response Analyzer
Purpose: To evaluate corneal visco-elasticity and intraocular pressure (IOP) changes measured by an Ocular Response Analyzer (ORA) after scleral buckling Methods: Fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated IOP (IOPcc) and Goldmann-correlated IOP (IOPg) were mea...
متن کاملcomparison of intraocular pressure measurements by the ocular response analyzer and goldmann applanation tonometer after penetrating keratoplasty in keratoconic patients
purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 kera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Environmental Research and Public Health
سال: 2019
ISSN: 1660-4601