Coriolis meter density errors induced by ambient air and fluid temperature differentials
نویسندگان
چکیده
منابع مشابه
Lifting of Ambient Air by Density Currents in Sheared Environments
Two aspects of vorticity associated with cold pools are addressed. First, tilting of horizontal vortex tubes by the updraft at a gust front has been proposed as a means of getting near-ground rotation and hence a tornado. Theory and a numerical simulation are used to show that this mechanism will not work because warm air parcels approaching the gust front decelerate in strong adverse pressure ...
متن کاملCoriolis Flow meter: A Review from 1989 to 2014
A consolidation of literature indicating the advances in the field of mass flow measurement is presently not available. Last published review paper on Coriolis mas flow meter (CFM) was in 2006. This work is an attempt is made to summarize the available works on Coriolis mass flow meter. The literature is classified into three major groups. The first group gives the summary of construction and t...
متن کاملCorrecting a Coriolis Meter for Two Phase Oil & Gas Flow
It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...
متن کاملROTAMASS 3 Series Coriolis Mass Flow and Density Meter - Achieving High - speed Measurement with High Accuracy and Robustness -
The Yokogawa Group has developed the ROTAMASS 3 series Coriolis flow and density meters. A Coriolis flowmeter can directly measure mass flow of fluid regardless of its temperature and pressure. The ROTAMASS 3 series meters have such unique features as fast signal processing, anti-vibration mechanism, and high accuracy density measurement. This paper describes these features and applications of ...
متن کاملThe effect of ambient pressure on laser-induced silicon plasma temperature, density and morphology
Laser-Induced Breakdown Spectroscopy (LIBS) of silicon was performed using a nanosecond pulsed frequency doubled Nd:YAG (532 nm) laser. The temporal evolution of the laser ablation plumes was characterized under a range of low pressures. Electron densities were determined from the Stark broadening of the Si (I) 288.16 nm emission line and were found to be in the range 2.79 × 10 cm to 5.59 × 10 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Flow Measurement and Instrumentation
سال: 2020
ISSN: 0955-5986
DOI: 10.1016/j.flowmeasinst.2020.101754