Cooling load differences between radiant and air systems
نویسندگان
چکیده
منابع مشابه
The Radiant Time Series Cooling Load Calculation Procedure
The radiant time series method is a new method for performing design cooling load calculations, derived from the heat balance method. It effectively replaces all other simplified (non-heat-balance) methods such as the cool#zg load temperature difference~solar cooling load~cooling load factor method (CLTD/SCL/CLF), the total equivalent temperature difference~time averaging method (TETD/TA), and ...
متن کاملSimulation of Radiant Cooling Performance with Evaporative Cooling Sources
This project addresses three closely related and similarly complex questions: First, using currently available simulation software, what methods might be appropriate for comparing slabintegrated radiant cooling to more conventional alternatives, such that the results are sufficiently fair and comprehensive to support system selection and design? Second, what is the relative performance of repre...
متن کاملDesign of a Radiant Panel Cooling System for Summer Air Conditioning System
The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملExperimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System
In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU). The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy and Buildings
سال: 2013
ISSN: 0378-7788
DOI: 10.1016/j.enbuild.2013.06.009