Convolution-based estimation of organ dose in tube current modulated CT
نویسندگان
چکیده
منابع مشابه
Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملUncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation
Background: Positron Emission Tomography-Computed Tomography (PET-CT) is a useful hybrid imaging modality in the diagnosis of various malignancies. This modality imposes almost 20 mSv radiation dose to the patient. The purpose of the present study was to evaluate the uncertainties in calculated CT effective dose in TUBE CURRENT MODULATION-activated scans by Impact-Dose software. Materials and ...
متن کاملthorax organ dose estimation in computed tomography based on patient ct data using monte carlo simulation
background: this study presents patient specific and organ dose estimation in computed tomography (ct) imaging of thorax directly from patient ct image using monte carlo simulation. patient's ct image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. materials and methods: egsnrc /beamnrc monte c...
متن کاملBismuth shielding, organ-based tube current modulation, and global reduction of tube current for dose reduction to the eye at head CT.
PURPOSE To compare the dose and image quality of three methods for reducing the radiation dose to the eye at head computed tomography (CT): bismuth shielding, organ-based tube current modulation (TCM), and global reduction of the tube current. MATERIALS AND METHODS An anthropomorphic head phantom was scanned under six conditions: (a) without any dose reduction techniques (reference scanning);...
متن کاملMeasurement of organ dose in chest CT examination using Monte Carlo simulation
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics in Medicine and Biology
سال: 2016
ISSN: 0031-9155,1361-6560
DOI: 10.1088/0031-9155/61/10/3935