Conversion Of A Severe Environmental Pollutant Electric Arc Furnace Dust (EAFD) To A Valuable Corrosion Inhibitor For Steel In Chloride Contaminated Reinforced Concrete Structures
نویسندگان
چکیده
منابع مشابه
Potential Reuse of Electric-Arc Furnace Dust (EAFD) in Concrete
This study investigated electric arc furnace dust (EAFD) reuse as a raw material in concrete mixes. A comprehensive experimental program consisting of two phases of testing was carried out. The first phase included the replacement of ordinary Portland (Type I) cement by unsieved dust with the percentages of 0, 2.5, 5, 7.5 and 10%. The second phase included the replacement of quartz (filler) by ...
متن کاملElectric Arc Furnace Slag and Blast Furnace Dust, Use for the Manufacture of Asphalt Concrete for Roads
This paper analyzes how feasible it is to use electric arc furnace slag as coarse aggregate, and blast furnace dust as fine aggregate in the manufacture of hot asphalt concrete for roads. Three mixtures were designed using the Ramcodes methodology, the M1 mixture of control with conventional materials, the M2 mixture replacing 50% and the M3 mixture replacing 100% of the conventional aggregates...
متن کاملMonitoring Corrosion of Steel Bars in Reinforced Concrete Structures
Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to pres...
متن کاملA KINETIC STUDY ON THE CARBOTHERMIC REDUCTION OF ZINC OXIDE FROM ELECTRIC ARC FURNACE DUST
In the present study, reduction of zinc oxide from the pellets made of steelmaking electric arc furnace dust has been investigated. Effects of such parameters as the type of carbon material (graphite, coke and charcoal) as well as time and temperature on the reduction reaction have been examined. The reduced (dimensionless) time method was applied to perform a kinetic analysis of the system. Ex...
متن کاملBrillouin Corrosion Expansion Sensors for Steel Reinforced Concrete Structures Using a Fiber Optic Coil Winding Method
In this paper, a novel kind of method to monitor corrosion expansion of steel rebars in steel reinforced concrete structures named fiber optic coil winding method is proposed, discussed and tested. It is based on the fiber optical Brillouin sensing technique. Firstly, a strain calibration experiment is designed and conducted to obtain the strain coefficient of single mode fiber optics. Results ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Civil & Environmental Engineering
سال: 2013
ISSN: 2165-784X
DOI: 10.4172/2165-784x.1000e111