Conventional versus reference-surface mass balance
نویسندگان
چکیده
منابع مشابه
Conventional versus reference-surface mass balance
Glacier surface mass balance evaluated over the actual glacier geometry depends not only on climatic variations, but also on the dynamic adjustment of glacier geometry. Therefore, it has been proposed that reference-surface balances calculated over a constant glacier hypsometry are better suited for climatic interpretation. Here we present a comparison of 82 year modelled time series (1926– 200...
متن کاملHeight, surface firmness, and visual reference effects on balance control.
OBJECTIVES To investigate the effects of height, surface firmness, and visual reference on standing balance in construction workers. DESIGN Controlled laboratory study with balanced repeated measures. PARTICIPANTS Twenty four construction workers. SETTING Test subjects performed standing tasks at ground level as well as at 3 m and 9 m high balconies on firm or deformable surfaces with clo...
متن کاملSurface mass-balance changes of the Greenland ice sheet
Mass loss from the Greenland ice sheet over the past decade has caused the impression that the ice sheet has been behaving anomalously to the warming of the 1990s. We have reconstructed the recent (1866–2005) surface mass-balance (SMB) history of the Greenland ice sheet on a 5 5 km grid using a runoff-retention model based on the positive degree-day method. The model is forced with new datasets...
متن کاملSurface mass balance contributions to acceleration of Antarctic ice mass loss during 2003–2013
Recent observations from satellite gravimetry (the Gravity Recovery and Climate Experiment (GRACE) mission) suggest an acceleration of ice mass loss from the Antarctic Ice Sheet (AIS). The contribution of surface mass balance changes (due to variable precipitation) is compared with GRACE-derived mass loss acceleration by assessing the estimated contribution of snow mass from meteorological rean...
متن کاملInfusible Platelet Membrane versus Conventional Platelet Concentrate: Benefits and Disadvantages
Blood transfusion centers are under considerable pressure to produce platelet concentrates with a shelf life limit of 3 to 5 days. Many approaches have been investigated experimentally to produce new hemostatically active platelet products that are capable of long term storage. In this article infusible platelet membrane will be explained as a platelet substitute versus conventional liquid-stor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Glaciology
سال: 2012
ISSN: 0022-1430,1727-5652
DOI: 10.3189/2012jog11j216