CONVECTIVE HEAT TRANSFER COEFFICIENT MEASUREMENT METHOD FOR INDOOR WALL JOINTS USING A RADIANT ENERGY THERMOMETER : Experimental studies on convective heat transfer coefficient for indoor wall joints Part 1
نویسندگان
چکیده
منابع مشابه
Experimental study of convective heat transfer coefficient of MgO nanofluid in a cylindrical microchannel heat sink
Convective heat transfer of MgO-water nanofluid in a microchannel heat sink is experimentally investigated in various concentrations of 0.01, 0.05, 0.1, and 0.6 wt%. The microchannel consisted of 48 parallel rectangular cross section channels with the height of 800 µm, width of 524 µm and length of 52 mm. A well stability duration (ca. 1 month) was resulted by a 180 min ultra-sonication of the ...
متن کاملDependency of thermal spreading resistance on convective heat transfer coefficient
This paper presents a study of the thermal spreading resistance Rth of a small heat source on a conductive substrate subject to bottomside convective cooling. This problem has been investigated for a very long time and is well covered in the literature. However, instead of using the design curves found in many papers, the results are presented as function of the heat transfer coefficient h. Doi...
متن کاملMeasurement of Local Convective Heat Transfer Coefficient of Alumina-Water Nanofluids in a Double Tube Heat Exchanger
Heat transfer coefficient and thermal efficiency of γ-Al2O3/water nanofluids flowing through a double tube heat exchanger were experimentally investigated. The nanoparticles were well dispersed in distilled water at 0.05–0.15 %vol. A large number of experiments were performed at different fluid flow rates under turbulent flow regime (18,000<Re<40,000) and various nanofluid...
متن کاملField Measurement of outside Convective Heat Transfer Coefficient on Horizontal Roof Using Naphthalene Sublimation Technique
The outside convective heat transfer coefficient (CHTC) of building roof is an important parameter for accurately calculating heat transfer through roof and simulating airflow around buildings. However, the correlations concerning CHTC in various studies seem to be discrepant. The experiment using naphthalene method to measuring CHTC was carried out on a nine-story building roof during 15 Augus...
متن کاملInfluence of Non-Uniform Wall Temperature on Local Heat Transfer Coefficient in a Rotating Square Channel
Abstract: This paper presents the results of an experimental examination of the effect of non-uniform wall temperature on local heat transfer coefficient in a rotating smooth-walled square channel. Three different thermal boundary situations were investigated: (a) even and odd (four) wall uniform temperature, (b) even and odd (four) wall uniform heat flux, and (c) even (leading and trailing) w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Architecture and Planning (Transactions of AIJ)
سال: 1999
ISSN: 1340-4210,1881-8161
DOI: 10.3130/aija.64.7_1