Controlling X-ray beam trajectory with a flexible hollow glass fibre
نویسندگان
چکیده
منابع مشابه
Controlling X-ray beam trajectory with a flexible hollow glass fibre
A metre-length flexible hollow glass fibre with 20 µm-bore and 1.5 mm-cladding diameters for transporting a synchrotron X-ray beam and controlling the trajectory has been examined. The large cladding diameter maintains a moderate curvature to satisfy the shallow glancing angle of total reflection. The observed transmission efficiency was more than 20% at 12.4 keV. As a demonstration, a wide-are...
متن کاملModification of Hollow Fibre Membranes through Electron Beam Irradiation
The capacity for secondary effluent filtration of hollow fiber polypropylene membranes grafted with several zwitterionic molecules and multi-walled carbon nanotubes was evaluated. In particular, all the modifications result in significant improvement of filtration performances. The anti-fouling properties of the membrane had been increased without damaging the membrane as observed from FTIR, TG...
متن کاملIdentification of glass and ceramics by X-ray fluorescence analysis with a pyroelectric X-ray generator.
Applications of X-ray fluorescence (XRF) analysis with a pyroelectric X-ray generator are presented. Glass and ceramics were analyzed with this novel X-ray generator to examine its capability for analyzing nonmetallic inorganic material. Although the power of X-ray output was a few orders of magnitude lower than conventional X-ray tubes, many elements such as Si, K, Ca, Ti, Cr, Fe, Zn, Sr, Ba, ...
متن کاملX-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.
PURPOSE The feasibility of medical imaging using a medical linear accelerator to generate acoustic waves is investigated. This modality, x-ray acoustic computed tomography (XACT), has the potential to enable deeper tissue penetration in tissue than photoacoustic tomography via laser excitation. METHODS Short pulsed (μs-range) 10 MV x-ray beams with dose-rate of approximately 30 Gy∕min were ge...
متن کاملOptimal Trajectory of Flexible Manipulator with Maximum Load Carrying Capacity
In this paper, a new formulation along with numerical solution for the problem of finding a point-to-point trajectory with maximum load carrying capacities for flexible manipulators is proposed. For rigid manipulators, the major limiting factor in determining the Dynamic Load Carrying Capacity (DLCC) is the joint actuator capacity. The flexibility exhibited by light weight robots or by robots o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Synchrotron Radiation
سال: 2013
ISSN: 1600-5775
DOI: 10.1107/s1600577513029706