Controlled potential coulometric determination of palladium
نویسندگان
چکیده
منابع مشابه
The coulometric determination of glucose in human serum.
The coulometric titration method is combined with the use of an enzymatic analytic reagent for the determination of glucose in human serum. The glucose in 25 ii. of serum is determined in a protein-free filtrate (PFF) with an accuracy of ± 3% and a coefficient of variation of approximately 2%. The procedure routinely covers a concentration range of 25-250 mg/100 ml. Calibrations are linear to a...
متن کاملA Coulometric Determination of Urea Nitrogen in Blood and Urine.
Since the ammonia undergoes a 3-electron change, 1 mole is equal to 3 equivalents of the generated titrant. Recently we (lescril)ed an improved cud-point (letection for this system and applied it to titration of as little as 1.4 g. ammonia (2). This method has been extended to titration of ammonia formed by the action of urease on urea in blood and urine. In urine samples, ammonia may be titrat...
متن کاملLow Parts per Billion Determination of Sulfide by Coulometric Argentometry
Present methods for the determination of sulfide in wastewater are hindered by poor detection limits and extensive sample pretreatment. A less problematic method has been developed with a method detection limit of 2.5 μg L-1. With this technique, sparged hydrogen sulfide is precipitated in an acetate-supporting electrolyte by electrogenerated silver ions. Analysis of basepreserved samples was p...
متن کاملExtraction - Spectrophotometric Determination of Palladium with Tetrabutyl Ammonium Iodide
A sensitive and selective extraction - spectrophotometric method for the determination of trace amounts of palladium is reported. The method is based on quantitative extraction of brownish tetrabutylammoium tetraiodopalladium (II) ion pair into a small valume of chloroform at pH 1.3-12.0, followed by spectrophotometric measurements. The Beer's law is obeyed over the range 0.02-1.09 <em...
متن کاملCoulometric determination of organic compounds. III. Determination of some phenoxazones by titanometric coulometry
Conditions have been found for the determination of some phenoxazones by titanometric coulometry using platinum electrode to generate Ti(III) ions, while the point of equivalency was recorded potentiometrically. It has been found, that correct and accurate results can be obtained when the amount of ethanol in the coulometric vessel is within 2—7 ml and the amount of the substance determined is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1965
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.14.259