Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

Two commercially available agar slide blood culture systems, Septi-Chek (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.) and VACUTAINER agar slant (Becton Dickinson [BD] Vacutainer Systems, Rutherford, N.J.), were compared in 5,628 paired blood cultures from adult patients. The systems were inoculated with equal volumes (5 ml) of blood. There was no statistically significant diffe...

متن کامل

Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Blood culture bottles that accept up to 10 ml of blood have recently been introduced for the BACTEC nonradiometric blood culture system. The new formulation, designated BACTEC Plus, contains 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. In a collaborative study conducted at three university hospitals, we evaluated the BACTEC Plus 26 (BP26) aerobic bottle and ...

متن کامل

Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

A commercially available agar-slide blood culture bottle (Septi-Chek; Roche Diagnostics, Div. Hoffman-La Roche, Inc., Nutley, N.J.) was compared with the radiometric blood culture system (BACTEC; Johnston Laboratories, Inc., Towson, Md.) in 8,544 paired blood cultures from adult patients. The systems were inoculated with equal volumes (10 ml) of blood. Overall, there was no statistically signif...

متن کامل

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disea...

متن کامل

on the comparison of keyword and semantic-context methods of learning new vocabulary meaning

the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 1989

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.27.12.2637-2639.1989