Controlled clinical comparison of Isolator and BACTEC 9240 Aerobic/F resin bottle for detection of bloodstream infections

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections.

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles w...

متن کامل

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disea...

متن کامل

Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...

متن کامل

Comparison of BACTEC 9240 Peds Plus medium and isolator 1.5 microbial tube for detection of Brucella melitensis from blood cultures.

The sensitivity and time to detection of Brucella melitensis by the BACTEC 9240 and the Isolator blood culture systems were compared in a prospective volume-controlled study. Blood sample aliquots, obtained from children with suspected brucellosis, were inoculated into a BACTEC 9240 Peds Plus bottle and into an Isolator 1.5 Microbial Tube. Overall, 122 pairs of blood samples for culture were ob...

متن کامل

Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

A total of 7,190 blood culture sets were obtained from adult patients with a suspected bloodstream infection. A 20-ml sample of blood was distributed equally between the aerobic FAN bottle which was monitored in the BacT/Alert system and a Plus Aerobic/F bottle which was monitored in the BACTEC 9240 system. A total of 988 positive cultures were obtained from 483 patients; however, only 453 posi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 1995

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.33.10.2525-2529.1995