Control Schemes for Auxiliary Switches of Three-Phase PWM Resonant Snubber Inverters
نویسندگان
چکیده
منابع مشابه
FPGA Realization of Space-Vector PWM Control IC for Three-Phase PWM Inverters
This paper presents a new circuit realization of the space-vector pulse-width modulation (SVPWM) strategy. An SVPWM control integrated circuit (IC) has been developed using the state-of-the-art field-programmable gate array (FPGA) technology. The proposed SVPWM control scheme can be realized using only a single FPGA (XC4010) from Xilinx, Inc. The output fundamental frequency can be adjusted fro...
متن کاملResonant snubber-based soft-switching inverters for electric propulsion drives
This paper summarizes recently developed soft-switching inverters and proposes two alternative options for electric propulsion drives. The newly developed soft-switching inverter employs an auxiliary switch and a resonant inductor per phase to produce a zero voltage across the main switch so that the main switch can turn on at the zero-voltage condition. Both the auxiliary switch and the resona...
متن کاملA New Voltage Control Method for Single-Phase PWM Inverters
A new voltage control method for single-phase full-bridge PWM inverters that having an output LC filter is proposed in this paper. The proposed voltage controller has a capability to realize a zero steadystate output voltage error with fast response. The zero steady-state output voltage error is achieved by using a controller that is derived by using the virtual LC resonant circuit. Fast respon...
متن کاملVoltage Control of Three Phase Inverters by Using Active Disturbance Rejection Control
Control of three phase inverters has been an important issue in recent years. This paper proposes active disturbance rejection control (ADRC) scheme for controlling three phase inverters. The main advantage of ADRC that motivated us for using this controller for inverter is that it is model independent. This controller is used in a double loop structure including an inner current loop and oute...
متن کاملTHREE SCHEMES FOR ACTIVE CONTROL OF THE PLANAR FRAME
Optimal locations of the actuators for frame active control are investigated in this article. The aim is to minimize the structural drifts by employing several actuators. By utilizing genetic algorithm, the appropriate locations of the actuators are determined. They should be placed in locations where they can minimize the maximum structural drift. To explore the capability of the proposed tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 2004
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.124.343