Contrast Echocardiography without Contrast Agent for Display of Intraventricular Mass
نویسندگان
چکیده
منابع مشابه
Localized Aortic Root Dissection Secondary to Contrast Agent Injection: Feasibility of Conservative Follow-up With Echocardiography
Introduction: Iatrogenic aortocoronary dissection (ACD) is a nightmare in interventional cardiology. Although ACD is rarely reported, the real-world prevalence is suspected of being higher due to unreported cases. The right coronary artery (RCA) ostium is involved in the majority of cases, and dissections are usually limited to the aortic sinus in half of the clinical presentat...
متن کاملSynthesized Gd2O3 nanoparticles as contrast agent
Introduction: Gd (III) ion has been known to be the best metal ion in the periodic table that can be used as a T1 MRI contrast agent. Gadolinium have 7 unpaired electrons and these electrons can make magnetic area. No other metal ions possess unpaired electron more than this. CAs based on the element Gd are classified as “positive”, by opposition to “negative” CAs. Nowadays, G...
متن کاملContrast Echocardiography
Ultrasound contrast agents are widely used in clinical practice for left ventricle opacification in sub-optimal echocardiograms. Recently, significant research has focused on the use of contrast echocardiography as a non-invasive means to evaluate myocardial perfusion. Advances in contrast agents as well as ultrasound technology have enabled investigations into myocardial contrast echocardiogra...
متن کاملContrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates
Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...
متن کاملInvestigation of acoustic properties of silica coated gold nanoparticle as contrast agent for Ultrasonography
Interoduction: Ultrasound images have often low contrast due to small differences in acoustic impedance between different tissues. Air or gas microbubbles that surrounded by membrane are most of the contrast agents in ultrasound imaging. Problems such as instability in sound pressure and inability in penetrating from the blood vessel into body tissues limited the use of microbubbles into the in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: CASE
سال: 2018
ISSN: 2468-6441
DOI: 10.1016/j.case.2018.01.004