The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferomet...
متن کاملGeneric Sensor Modeling for Modulation Transfer Function (mtf) Estimation
An imaging sensor’s spatial quality can be expressed by the system’s point spread function (PSF). The PSF of a pushbroom Charge-Coupled Device (CCD) satellite sensor was numerically modeled including contributions from optic, detector, sensor motion, and electronic components. Synthetic edge and pulse targets with various intensity levels were developed and then convolved with the generic senso...
متن کاملMeasurement and compensation of printer modulation transfer function
bstract. The capacity of a printing system to accurately reproduce etails has an impact on the quality of printed images. The ability of system to reproduce details is captured in its modulation transfer unction (MTF). In the first part of this work, we compare three exsting methods to measure the MTF of a printing system. After a horough investigation, we select the method from Jang and Alleac...
متن کاملModulation transfer function measurement of a multichannel optical system.
We present a new method to measure the modulation transfer function (MTF) beyond the Nyquist frequency of a multichannel imaging system for which all the channels have parallel optical axes. Such a multichannel optical system produces a set of undersampled subimages. If the subimages contain nonredundant information, high spatial frequencies are folded between low spatial frequencies, leading t...
متن کاملAberration measurement using the Ronchigram contrast transfer function.
The bright field contrast transfer function is one of the most useful concepts in conventional transmission electron microscopy. However, the electron Ronchigram contrast transfer function, as derived by Cowley, is inherently more complicated since it is not isoplanatic. Here, we derive a local contrast transfer function for small patches in a Ronchigram and demonstrate its utility for the dire...