Determination of permeability and diffusivity of oxygen in polymers by polarographic method with inert gas
A modified polarographic method with inert gas for determination of the oxygen permeability in polymers immersed in liquids is described. Owing to the stream of an inert gas towards polymer from the cathode side, lateral oxygen diffusion (edge effects) is minimized. Unlike the standard Fatt method, the method with inert gas is suitable also for thick samples and, therefore, for high-permeable m...
متن کاملPolarographic determination of oxygen tension of whole blood.
The purpose of this study is to establish a procedure for the direct determination of oxygen tension of whole blood that requires a smaller sample and simpler manipulation than methods previously reported (1). A procedure has been worked out for determining dissolved plasma oxygen which proved satisfactory in our investigations. Since the success of the application of the proposed polarographic...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Polarographic Oxygen Electrode
A method has been developed for the continuous monitoring of oxygen tension in solutions and gases. The oxygen is reduced at a platinum surface which is covered with a plastic membrane. The silver-silver oxide reference electrode is also included under the membrane. Drift is less than 10 per cent for a period of days, and temperature compcnsation is possible. A number of uses to which it has be...
متن کاملPolarographic determination of malononitrile.
A procedure is proposed for the determination of malononitrile by differential pulse polarography in methanolic 0.1M tetraethylammonium iodide/0.001M tetramethylammonium hydroxide as the supporting electrolyte. In this medium malononitrile is chemically converted into an electroactive species. With close control of timing of the steps in the procedure the error of the method is +/-1.5% in the c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1964
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.13.627