Continuous monitoring of mixed venous oxygen saturation during aortic surgery.

The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...

متن کامل

Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content

Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...

متن کامل

Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand.

Because central venous O2 saturation (superior vena cava, ScvO2) can be monitored with less patient risk than mixed venous O2 saturation (pulmonary artery, SvO2), we examined the correlations between SvO2 and ScvO2 over a broad range of cardiorespiratory conditions, including hypoxia, hemorrhage, and resuscitation in anesthetized dogs. The correlation coefficient (r) between SvO2 and ScvO2 in 1...

متن کامل

Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions.

BACKGROUND Previous studies found contradictory results regarding the question whether mixed venous oxygen saturation (Svo2) and central venous oxygen saturation (Scvo2) are equivalent. The inconsistency of study results may result from different study designs and different, partly questionable, statistical approaches. METHODS The authors performed a prospective clinical trial comparing indiv...

متن کامل

Challenges associated with central venous catheter placement and central venous oxygen saturation monitoring.

Patients with septic shock and respiratory failure often require hemodynamic monitoring in order to guide bedside management. This is particularly true of patients with dialysis-dependent chronic kidney disease, who may be less tolerant of large volume resuscitation than individuals with normal renal function. With the declining use of pulmonary artery catheters and the introduction of early go...