Continuous measurement of contact heat flux during minced meat grilling
نویسندگان
چکیده
منابع مشابه
Non-invasive continuous core temperature measurement by zero heat flux.
Reliable continuous core temperature measurement is of major importance for monitoring patients. The zero heat flux method (ZHF) can potentially fulfil the requirements of non-invasiveness, reliability and short delay time that current measurement methods lack. The purpose of this study was to determine the performance of a new ZHF device on the forehead regarding these issues. Seven healthy su...
متن کاملMeasurement of Heat Flux and Heat Transfer Coefficient During Continuous Cryogen Spray Cooling for Laser Dermatologic Surgery
Cryogen spray cooling (CSC) has been used for selective epidermal cooling of human skin during laser therapy of patients with port wine stain (PWS) birthmarks. Unfortunately, current commercial CSC devices do not provide optimal cooling selectivity and, therefore, provide insufficient epidermal protection for some PWS patients. To assist in the development of improved atomizing nozzle designs, ...
متن کاملDevelopment of a Direct-Measurement Thin-Film Heat Flux Array
A new thin film heat flux array (HFA) was designed and constructed using a series of nickel/copper thermocouples deposited onto a thin Kapton® polyimide film. The HFA is capable of withstanding temperatures up to 300°C and produces signals of 40 μV/(W/cm). As a result of its thin film construction, the HFA is able to resolve heat flux signals as fast as 32 ms. Calibrations were completed to det...
متن کاملMeasurement of Boundary Conditions - Surface Heat Flux and Surface Temperature
In order to understand a heat transfer phenomenon, it is sometimes very important to know the change in heat flux and temperature with time or the distribution of the heat flux and temperature on the surface of a heating block. Furthermore, with the development of computational thermal-fluid dynamics, experimental data that are of the CFD level, both spatially and temporally, are needed to vali...
متن کاملTransient heat flux measurement using a surface junction thermocouple
A new form of surface junction thermocouple sensor has been developed and tested. The novel feature of the design is the use of a tapered fit between two coaxial thermocouple elements to form a thin, robust junction. The gauge has a response time on the order of 1 ms and is suitable for measuring large transient heat fluxes in hypervelocity wind tunnels. Asymptotic analysis is used to demonstra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Food Engineering
سال: 2019
ISSN: 0260-8774
DOI: 10.1016/j.jfoodeng.2018.08.032