Continuous Limb Blood Flow Estimation in the Newborn Using Electrical Impedance Plethysmography
نویسندگان
چکیده
منابع مشابه
Evaluation of cardiac parameters using electrical impedance plethysmography.
UNLABELLED Impedance plethysmography is a method for determining changes in body tissue volumes, based on the measurement of electric impedance at the body surface. Because it is a non-invasive and cost-effective method to measure and analyze hemodynamics, it would bring to physiologists very important diagnostic information for the continuous care of critical patients with hemodynamic disorder...
متن کاملElectrical impedance alterations in the rat hind limb with unloading.
OBJECTIVES Methods are needed for quantifying muscle deconditioning due to immobilization, aging, or spaceflight. Electrical impedance myography (EIM) is one technique that may offer easy-to-follow metrics. Here, we evaluate the time course and character of the change in single- and multi-frequency EIM parameters in the hind-limb suspension model of muscle deconditioning in rats. METHODS Sixt...
متن کاملImplantable Impedance Plethysmography
We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملLimitations of electric impedance plethysmography.
Klectrie impedance plethysmography has been offered as a substitute for mechanical plethysmography and would be particularly suitable for regions in which the mechanical method cannot be applied. A comparative investigation of mechanical and impedance plethysmograms, taken simultaneously from a finger or a forearm, revealed that, while the normal pulsations were reproduced reasonably well, elec...