Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EMERGING TECHNOLOGIES Continuous Intravascular Blood Gas Monitoring

N AVERAGE adult at rest consumes approximately A 100 million trillion molecules of oxygen per second; with virtually no capacity for oxygen storage, cessation of oxygen delivery quickly results in irreversible cellular damage. The human cardiopulmonary system functions remarkably well in healthy individuals, maintaining the mitochondrial oxygen tension (greater than 1 mmHg) required for aerobic...

متن کامل

Clinical assessment of a continuous intraarterial blood gas monitoring system.

We evaluated the clinical performance of a continuous intraarterial blood gas monitoring (CIABG) system which includes a fluorometric intravascular sensor. Seventeen patients undergoing elective surgery were monitored perioperatively with the CIABG system (PB3300; Puritan Bennett, Carlsbad, CA). Conventional laboratory blood gas analyses (BGA) were performed simultaneously whenever indicated, a...

متن کامل

Toward a Continuous Intravascular Glucose Monitoring System

Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. ...

متن کامل

Clinical Use of Professional Continuous Glucose Monitoring

The costs of managing diabetes are growing at an unsustainable rate. According to the ADA website, the cost (direct and indirect) in 2012 was $245 billion and continues to grow. As clinicians, we fully appreciate that lowering the A1c is one of the keys to lowering the costs associated with diabetes complications. It has been estimated that lowering the A1c across all patients with diabetes by ...

متن کامل

Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices.

Perioperative monitoring of blood coagulation is critical to better understand causes of hemorrhage, to guide hemostatic therapies, and to predict the risk of bleeding during the consecutive anesthetic or surgical procedures. Point-of-care (POC) coagulation monitoring devices assessing the viscoelastic properties of whole blood, i.e., thrombelastography, rotation thrombelastometry, and Sonoclot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 2003

ISSN: 0007-0912

DOI: 10.1093/bja/aeg176