Continuous intra-arterial blood gas monitoring during oesophagectomy
نویسندگان
چکیده
منابع مشابه
Continuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass.
We measured the accuracy of the continuous intra-vascular blood-gas monitoring system (Paratrend 7, PT7) placed in the jugular venous bulb in 18 adult patients having cardiac or aortic surgery with hypothermic cardiopulmonary bypass (CPB). After induction of anaesthesia, a PT7 sensor was inserted through a 20-gauge venous catheter into the right jugular venous bulb. Blood samples were drawn fro...
متن کاملInterpretation of Arterial Blood Gas
تجزیه و تحلیل گازهای خون اطلاعات مهمی را در مورد اکسیژناسیون شریانی و تعادل اسید - باز در دست ما قرار می دهد. در ک این داده ها بخشی اساسی از مراقبت پرستاری در اکثر بیماران است. هنوز برای بسیاری از پرستاران، تفسیر نتایج گازهای خون شریانی همانند یک جدول پیچیده بوده و در مواقعی که بررسی تمام نتایج در اسرع وقت مورد نیاز باشد، این مشکل بیشتر نمایان می شود.
متن کاملEMERGING TECHNOLOGIES Continuous Intravascular Blood Gas Monitoring
N AVERAGE adult at rest consumes approximately A 100 million trillion molecules of oxygen per second; with virtually no capacity for oxygen storage, cessation of oxygen delivery quickly results in irreversible cellular damage. The human cardiopulmonary system functions remarkably well in healthy individuals, maintaining the mitochondrial oxygen tension (greater than 1 mmHg) required for aerobic...
متن کاملContinuous fiberoptic arterial and venous blood gas monitoring in hemorrhagic shock.
STUDY OBJECTIVE To compare the performance of continuous fiberoptic blood gas monitoring with standard, intermittent blood gas sampling in the measurement of arterial and central venous blood gases during marked hemodynamic changes. DESIGN Prospective, consecutive, enrollment, experimental study. SETTING Research laboratory at a university medical center. PARTICIPANTS Seven anesthetized, ...
متن کاملGelsomino 1 Assessment of a Continuous Blood Gas Monitoring System in Animals during Circulatory stress. Short Title: Continuous Blood Gas Monitoring
Introduction: The study was aimed to determine the measurement accuracy of The CDI TM blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods: Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Argininevasopres...