Continuous Glucose Monitoring in the Subcutaneous Tissue over a 14-Day Sensor Wear Period

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

BACKGROUND Glucose monitoring systems using subcutaneously inserted sensors are currently labeled for up to 7 days of wear. In this study, we evaluated the feasibility of a 14-day wear duration using a modified version of the sensor found in the Freestyle Navigator™ continuous glucose monitoring system. METHODS Sixty-two subjects with diabetes were enrolled in the study. One sensor per subjec...

متن کامل

Continuous Glucose Sensor Survival and Accuracy Over 14 Consecutive Days

Continuous glucose monitoring (CGM) technology provides real-time glucose data and the ability to achieve improved glycemic control; however, widespread adoption has been limited (1). Among the challenges to CGMuptake are cost and the inconvenience of changing the sensor. In this prospective, multicenter study, theDexcomG4PLATINUMsystemwas analyzed over 14 days of continuous sensor wear. Each s...

متن کامل

Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.

The feasibility of continuous long-term glucose monitoring in humans has not yet been demonstrated. Enzyme-based electrochemical glucose sensors with telemetric output were subcutaneously implanted and evaluated in five human subjects with type I diabetes. Subject-worn radio-receiver data-loggers stored sensor outputs. Every 1-4 weeks the subject's glucose levels were manipulated through the fu...

متن کامل

Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.

OBJECTIVE This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose va...

متن کامل

Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis.

OBJECTIVE To evaluate the accuracy of a new subcutaneous glucose sensor (Glucoday; A. Menarini Diagnostics) compared with venous blood glucose measurement in type 1 and type 2 diabetic patients. RESEARCH DESIGN A multicenter study was performed in 70 diabetic patients. A microdialysis fiber was inserted subcutaneously into the periumbelical region and perfused with a buffer solution. Glucose ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Diabetes Science and Technology

سال: 2013

ISSN: 1932-2968,1932-2968

DOI: 10.1177/193229681300700511