Electrospun Fibers of Cyclodextrins and Poly(cyclodextrins).
Cyclodextrins (CDs) can endow electrospun fibers with outstanding performance characteristics that rely on their ability to form inclusion complexes. The inclusion complexes can be blended with electrospinnable polymers or used themselves as main components of electrospun nanofibers. In general, the presence of CDs promotes drug release in aqueous media, but they may also play other roles such ...
متن کاملSolubilization of vorinostat by cyclodextrins.
BACKGROUND Vorinostat (suberoylanilide hydroxamic acid) is the first histone deacetylase inhibitor approved by US FDA for use in oncology. However, as a hydrophobic acid, its limited aqueous solubility poses a problem for parenteral delivery. Such limited solubility may also affect its oral bioavailability. OBJECTIVE The aim of this study was to evaluate whether cyclodextrins (CDs), common ex...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...