Liquid sodium is the heat transport medium in fast breeder reactors due to its favorable chemical, physical, and nuclear properties. Wetting of liquid with material reactor components essential for effective functioning reactor. wetting plays a crucial role, such as (i) transfer (ii) image reconstruction under ultrasonic scanners. Contact angle inverse measure liquids over solid surfaces. A contact measurement system was set up an inert atmosphere glow box study behavior on materials. The nickel surface measured function temperature, results obtained were found be good agreement literature values. SS316LN temperature first time using this facility.
منابع مشابه
Reliable measurement of the receding contact angle.
Surface wettability is usually evaluated by the contact angle between the perimeter of a water drop and the surface. However, this single measurement is not enough for proper characterization, and the so-called advancing and receding contact angles also need to be measured. Measuring the receding contact angle can be challenging, especially for extremely hydrophobic surfaces. We demonstrate a r...
متن کاملMeasurement of Critical Contact Angle in a Microgravity Space Experiment
Mathematical theory predicts that small changes in container shape or in contact angle can give rise to large shifts of liquid in a microgravity environment. This phenomenon was investigated in the Interface Configuration Experiment on board the NASA USML-2 Space Shuttle flight. The experiment’s “double proboscis” containers were designed to strike a balance between conflicting requirements of ...
متن کاملEquilibrium gas–liquid–solid contact angle from density-functional theory
We investigate the equilibrium of a fluid in contact with a solid boundary through a density-functional theory. Depending on the conditions, the fluid can be in one phase, gas or liquid, or two phases, while the wall induces an external field acting on the fluid particles. We first examine the case of a liquid film in contact with the wall. We construct bifurcation diagrams for the film thickne...
متن کاملA new thoron atmosphere reference measurement system.
A new thoron reference ((220)Rn) in air measurement system is developed at the LNE-LNHB with the collaboration of the IRSN. This measurement system is based on a reference volume with an alpha detector which is able to directly measure thoron and its decay products at atmospheric pressure. In order to improve the spectrum quality of the thoron progenies, we have applied an electric field to cat...
متن کاملNUCLEATION OF Sb-MICROCRYSTALS IN AN INERT-GAS ATMOSPHERE
The generation of antimony clusters in the size range from Sb to SbSoo is reported. The clusters are created by inert gas condensation and detected by a time-ofiflight mass spectrometer. Condensation of clusters of knvwn sizes onto a cold substrate is suggested as a technique which enables investigations of amorphous substances as a function of order. To reveal the topology of amorphoussolids a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2023
ISSN: ['1089-7623', '1527-2400', '0034-6748']
DOI: https://doi.org/10.1063/5.0151599