Construction and Evaluation of a Multipurpose Performance Check Phantom for Computed Tomography
نویسندگان
چکیده
منابع مشابه
Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملcomputed tomography colonography phantom: construction, validation and literature review
conclusion we constructed and validated a ct colonography phantom with correct density allowing performance of reproducible experiments. materials and methods we found 15 different phantom designs by literature search and compared their advantages and disadvantages based on their description and images. we tested various materials for density and mechanical properties and constructed a phantom ...
متن کاملComputed Tomography Colonography Phantom: Construction, Validation and Literature Review
BACKGROUND Several dedicated computed tomography (CT) colonography phantoms have been described previously. OBJECTIVES To compare their pros and cons and describe the construction of a dedicated phantom that can be easily manufactured. MATERIALS AND METHODS We found 15 different phantom designs by literature search and compared their advantages and disadvantages based on their description a...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملDevelopment of Computed Tomography Head and Body Phantom for Organ Dosimetry
Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...