CONSTRUCTAL DESIGN OF A TUBULAR ARRAY SUBJECTED TO FORCED CONVECTION
نویسندگان
چکیده
منابع مشابه
Evaporation of a sessile water droplet subjected to forced convection in humid environment
The evaporation of a sessile droplet is here investigated numerically with a design of experiment approach. Boundary conditions are chosen based on forced convection in humid air, i.e., mimicking the conditions inside a dishwasher. Computational fluid dynamic simulations of an axisymmetrical droplet placed on a heated plate show that relative humidity, initial contact angle, plate temperature, ...
متن کاملConcrete Filled Tubular Bracing Subjected to Cyclic Loading
The energy absorption of concrete filled, hollow-steel bracing was analyzed respect to geometric and mechanical parameters including the width-to-thickness section ratio, slenderness level, and strength of the steel and concrete. Local buckling and ductility were also investigated with respect to variation in the cross-section. The infill increased the compression resistance, even after multipl...
متن کاملForced-Vibration Analysis of a Coupled System of SLGSs by Visco- Pasternak Medium Subjected to a Moving Nano-particle
In this study, forced-vibration analysis of a coupled system of single layered graphene sheets (SLGSs) subjected to the moving nano-particle is carried out based on nonlocal elasticity theory of orthotropic plate. Two SLGSs are coupled with elastic medium which is simulated by Pasternak and Visco-Pasternak models. Using Hamilton’s principle, governing differential equations of motion are derive...
متن کاملA Constructal Approach to Power Distribution Networks Design
Superior, scalable grid topology that may provide for higher quality of service, survivorship capacity, and reconfiguration capability is a feature of modern grid architecture. The reported research is aimed at delivering a possible, constructal solution that is based on a minimumredundant, scalable, reconfigurable topology that helps increasing the grid immunity to faults. We assume that a tre...
متن کاملBurnout in Forced Convection
Data are presented for burnout in forced coivection nucleate boiling of water at pressures above 500 psia. A dimensionless correlation is devised for. the M.I.T. data which is found to be valid for certain recent data reported by Argonne National Laboratory.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Revista de Engenharia Térmica
سال: 2015
ISSN: 1676-1790
DOI: 10.5380/reterm.v14i1.62108