Constrained reconstruction applied to 2-D chemical shift imaging
نویسندگان
چکیده
منابع مشابه
Echoplanar chemical shift imaging.
A novel method of chemical shift imaging utilizing echoplanar imaging (EPI) has been developed for the purpose of improving the spatial resolution of metabolite images for the specific goal of high spatial resolution mapping of neuronal content. An EPI sequence was modified to allow temporal offsets of the 180 degree refocusing pulse that encode the chemical shift information into the phase of ...
متن کاملTemporally constrained reconstruction applied to MRI temperature data.
The monitoring of thermal ablation procedures would benefit from an acceleration in the rate at which MRI temperature maps are acquired. Constrained reconstruction techniques have been shown to be capable of generating high quality images using only a fraction of the k-space data. Here, we present a temporally constrained reconstruction (TCR) algorithm applied to proton resonance frequency shif...
متن کاملApplications of Chemical Shift Imaging to Marine Sciences
The successful applications of magnetic resonance imaging (MRI) in medicine are mostly due to the non-invasive and non-destructive nature of MRI techniques. Longitudinal studies of humans and animals are easily accomplished, taking advantage of the fact that MRI does not use harmful radiation that would be needed for plain film radiographic, computerized tomography (CT) or positron emission (PE...
متن کاملAdiabatic Spiral Correlation Chemical Shift Imaging
Introduction The overlap of spectra in magnetic resonance spectroscopy limits the unambiguous identification and quantification of metabolites. Two of the most employed approaches involve fitting with a known basis set [1] and spectral editing [2]. Alternatively, multidimensional correlation spectroscopy [3] does not need to assume a certain basis set, nor needs to filter-out metabolites as in ...
متن کاملNatural linewidth chemical shift imaging (NL-CSI).
The discrete Fourier transform (FT) is a conventional method for spatial reconstruction of chemical shifting imaging (CSI) data. Due to point spread function (PSF) effects, FT reconstruction leads to intervoxel signal leakage (Gibbs ringing). Spectral localization by imaging (SLIM) reconstruction was previously proposed to overcome this intervoxel signal contamination. However, the existence of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Medical Imaging
سال: 1997
ISSN: 0278-0062
DOI: 10.1109/42.640749