Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System
نویسندگان
چکیده
منابع مشابه
Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System
The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a...
متن کاملMulti-analyte surface plasmon resonance biosensing.
Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultane...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولA localized surface plasmon resonance imaging instrument for multiplexed biosensing.
Localized surface plasmon resonance (LSPR) spectroscopy has been widely used for label-free, highly sensitive measurements of interactions at a surface. LSPR imaging (LSPRi) has the full advantages of LSPR but enables high-throughput, multiplexed measurements by simultaneously probing multiple individually addressable sensors on a single sample surface. Each spatially distinct sensor can be tai...
متن کاملDesign and implementation of a portable physiologic data acquisition system.
OBJECTIVE To describe and report the reliability of a portable, laptop-based, real-time, continuous physiologic data acquisition system (PDAS) that allows for synchronous recording of physiologic data, clinical events, and event markers at the bedside for physiologic research studies in the intensive care unit. DESIGN Descriptive report of new research technology. SETTING Adult and pediatri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2015
ISSN: 1424-8220
DOI: 10.3390/s150820511