Linear Accelerator Shielding : Thirty Years Beyond NCRP 49

The purpose of this review is to discuss particular shielding problems related to highenergy machines that are not covered in NCRP report No. 49. These include calculating the dose at the end of a maze due to neutrons and capture rays, consideration of high-energy direct-shielded doors, and laminated primary shielding. The impact of special procedures such as IMRT, TBI, and SRS will also be dis...

متن کامل

A (cern) History of Accelerator Shielding

This paper provides an historical overview of accelerator shielding of accelerator shielding studies at CERN. CERN accelerators and the related shielding problems span 50 years of history and cover all major aspects which can be encountered in accelerator radiation protection. Namely: various accelerated particles (electrons, positrons, protons, antiprotons, heavy ions), a wide range of energie...

متن کامل

Treatment vault shielding for a flattening filter-free medical linear accelerator.

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

متن کامل

Shielding evaluation for IMRT implementation in an existing accelerator vault

A formalism is developed for evaluating the shielding in an existing vault to be used for IMRT. Existing exposure rate measurements are utilized as well as a newly developed effective modulation scaling factor. Examples are given for vaults housing 6, 10 and 18 MV linear accelerators. The use of an 18 MV Siemens linear accelerator is evaluated for IMRT delivery with respect to neutron productio...

متن کامل

Measuring the Skyshine from Linear accelerator in Rajaee Oncology Hospital

Introduction: Radiation therapy is using the ionizing radiation to eliminate or minimize cancerous tissues. This method has been very much considered in recent years. Because of the high energy of the photons produced by the accelerator, it is necessary to protect the walls, roof and the floor of the treatment rooms using the concrete and leaden materials. One of these harmful ...