Conoscopic holography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conoscopic holography.

A new method for recording holograms using incoherent light is described. The method is based on optical propagation through birefringent crystals. Optical methods for the reconstruction of such a hologram are also presented.

متن کامل

Conoscopic holography: toward three-dimensional reconstructions of opaque objects.

Conoscopic holography is an interferometric technique that permits the recording of three-dimensional objects. A two-step scheme is presented to recover an opaque object's shape from its conoscopic hologram, consisting of a reconstruction algorithm to give a first estimate of the shape and an iterative restoration procedure that uses the object's support information to make the reconstruction m...

متن کامل

Conoscopic Holography for Image Registration: A Feasibility Study

Preoperative image data can facilitate intrasurgical guidance by revealing interior features of opaque tissues, provided image data can be accurately registered to the physical patient. Registration is challenging in organs that are deformable and lack features suitable for use as alignment fiducials (e.g. liver, kidneys, etc.). However, provided intraoperative sensing of surface contours can b...

متن کامل

3d Conoscopic Holography in View of Retinal Imaging

In vivo high-resolution eye fundus imaging is a much-needed tool for early diagnosis of retinal diseases such as AMD and for the follow-up of such pathologies. One way to obtain high-resolution 3D images of the retina is to use an Adaptive Optics (AO) corrected conventional microscope (with no optical sectioning capacity) and to perform the optical sectioning a posteriori, digitally, via 3D dec...

متن کامل

On-Line Metrology with Conoscopic Holography: Beyond Triangulation

On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Letters

سال: 1985

ISSN: 0146-9592,1539-4794

DOI: 10.1364/ol.10.000004