To serve its purpose a structure must be safe against collapse and serviceable in use. Serviceability requires that deflections be adequately small to keep the cracks within tolerable limits. Although the widely followed ACI Code suggests a detailed method of deflection calculation, it often cannot exactly perceive the actual behavior of a structure. For this purpose, finite element analysis, u...
متن کاملFull Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems
This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of reinforced concrete (RC) beam-column joints strengthened with steel reinforced polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in...
متن کاملPerformance-based Optimization of Strut-and-tie Models in Reinforced Concrete Beam-column Connections
This paper presents the performance-based optimization of strut-and-tie models in reinforced concrete beam-column connections. The performance-based optimization (PBO) technique is employed to investigate optimal strut-and-tie models in reinforced concrete beam-column connections. Developing strut-and-tie models in reinforced concrete beam-column connections is treated as a topology optimizatio...
متن کاملMathematical Modeling of Column-Base Connections under Monotonic Loading
Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...
متن کاملFinite Element Modeling of GFRP-Reinforced Concrete Interior Slab-Column Connections Subjected to Moment Transfer
A finite element model (FEM) was constructed using specialized three-dimensional (3D) software to investigate the punching shear behavior of interior slab-column connections subjected to a moment-to-shear ratio of 0.15 m. The FEM was then verified against the experimental results of full-scale interior slab-column connections reinforced with glass fiber reinforcement polymer (GFRP) bars previou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan
سال: 1980
ISSN: 0387-1185,2433-0027
DOI: 10.3130/aijsaxx.287.0_39