Conduction disturbances caused by high current density electric fields.

During internal defibrillation, potential gradients greater than 100 V/cm occur near defibrillation electrodes. Such strong fields may cause deleterious effects, including arrhythmias. This study determined 1) the effects of such strong fields on the propagation of activation and 2) whether these effects were different for monophasic and biphasic shocks. Voltages and potential gradients during ...

متن کامل

Conduction and Electrostriction of Polymers Induced by High Electric Fields

After reviewing the new physics and chemistry in high electrostatic fields we use density functional theory to show that in fields around 1.5 V/Å the bandgap of polythiophene reduces to zero leading to field-induced metallization. In poly(ethylene glycol), on the other hand, such fields lead to giant electrostriction of over 20% in length. Lastly, we give two examples of field-induced polymeriz...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

Enhancement of Current Density by dc Electric Concentrator

We investigate a dc electric concentrator for steady current fields theoretically and experimentally. Based on the transformation electrostatics, we show that the dc concentrator can focus electric currents into the central concentrated region and enhance the electric field and current density. Outside the concentrator, the current lines are distributed as the same as those in a homogeneous con...

متن کامل

Arrhythmias and Conduction Disturbances

Coupling intervals of extrastimuli that induced 57 previously documented unimorphic ventricular tachycardias (VTs) were compared with coupling intervals that induced 57 episodes of polymorphic VT or ventricular fibrillation (VF) in patients wlthout a documented or suspected history of polymorphic VT or VF. Programmed stimulation was performed with the patient in the drug-free state, with 1 to 3...